Total Inspection Process
Purpose
- Aging on/off test
- Aging Time : 60 max.
- Aging Pallet : 60ea.
(300mm x 1,200mm : 120ea)
Features
- Double Layer Simultaneous Testing
- Wide variety of aging processes
Voltage and Insulation Resistance Testing
Purpose
- Assembly Inspections
- Module Inspections
- Outcome : Pass/Fail
Measured Ratings
- Voltage : 0V ~ 5KV
- Insulation Resistance
- SW : Pass/Fail
Characteristic Testing
Purpose
- LED Lighting Inspection via Vision Camera
- Module Measurements
- Outcome : Pass/Fail
Measured Ratings
- Lumens (lm), CCT (K)
- Chromaticity ( x, y ), Efficacy (lm/w)
- Watts (W), Amperage (A), Voltage (V)
- Power Factor, Harmonic Distortion
Features
- Data Saving
- Testing Criteria Selectable
Die-Casting Machine
Die-Casting Machine & Full Automatic robot
Coating Line
Coating Line (Ceramic Coating & Powder Coating)
Production